Chapter 1
2
The transmitter must be relatively close-coupled to the probe in order to achieve this improved
performance. This is achieved by direct connection to the probe through short probe-connecting
adapter, or in the case of some retractable probes through a cable of no more than 2 meters (6
feet) length.
A typical installation of a Corrater transmitter is on a high pressure access fitting with a flexible
conduit connection cable. The transmitter and the connectors that attach to it are explosion-proof
(flame-proof).
Warning: Power must be removed before disconnecting either connector on the
transmitter if explosive gases are present
The Corrater transmitter may be used for continuous on-line monitoring systems with or without
Microcor transmitters. The 24 VDC power supply and the RS 485 communications in an online
system allow multi-drop connections between the central corrosion monitoring computer and all
of the transmitters, which minimizes cabling costs. Each transmitter has internal DIP switches to
set the Identification Number or Address of the transmitter from 0 to 31 for communications
over the two-wire RS 485 bus.